For more information or advice on our control products and how Hawco can assist you please call +44 (0) 1483 869100. Order before 5pm online or 6pm over phone for next-day delivery throughout the UK. Buy Bimetal Thermostat Ty60 CAMPINI 160°C NC 16A, 250 VAC for €3.58 through. Model - Ty60 CAMPINI;; type - bimetallic, manually restored;; shut-off.
Q: Hi I've got one of these thermostat fitted on my stainless steel 180 ltr water tank. Everything has run fine for several years, however I have just got fitted solar electric fitted on my roof. This sends the excess power to the Emersion element on the tank. I set this thermostat to maximum 85deg just because it would heat the water for free.
My issue is when the sun stopped heating the tank I was expecting the gas to cut in and heat the water however this thermostat had tripped out. This took me a while to trace Is there a maximum temperature before this thermostat trips out or is there another fault. Should I set the temperature of the solar side lower to avoid this. Hope this is understandable and any help would be very help full Paul A: Yes, if the water goes above 85C the limit safety stat will kick in and you will need to manually reset it before you can use it. This is a safety feature in case the main control thermostat fails. I would recommend lowering the immersion thermostat to 65C.
To avoid it throwing the limit safety thermostat and to lower the risk of scalding.
Mid Efficiency Ducted Gas Heater. Owner’s Manual Page 6 CONTROL OPTIONS. Manual Wall Thermostat - Campini To operate your Mid Efficiency Ducted Central Heater fitted with this manual wall control: - 1. To turn ON, slide the ON / OFF switch up to the ON position.
Adjust the thermostat knob to the desired temperature. To turn OFF, slide the ON / OFF switch down to the OFF position. The function of the room thermostat is to maintain the room temperature at the set point selected.
Once the heater has reached set temperature the unit will stop. Once the room temperature has dropped below the set point the unit will restart maintaining the set temperature. Electronic Wall Thermostat - Honeywell To operate your Mid Efficiency Ducted Gas Central Heater fitted with this electronic wall control: - 1.
Open the door of the thermostat 2. Press the system button to select Heat. Selecting the set temperature.
Press the HOLD TEMP button. This will over ride any programs set. Using the ▲ ▼ buttons by the screen display to adjust the set temperature.
For heating if the set temperature is greater than the room temperature the flame symbol will appear by heating to indicate the heater is operating. To check set temperature press the i button under the ▲ ▼ buttons. To turn the thermostat off.
Open the door of the thermostat. Press the system button to select until the OFF appears. The function of the room thermostat is to maintain the room temperature at the set point selected. Once the heater has reached set temperature the unit will stop. Once the room temperature has dropped below the set point the unit will restart maintaining the set temperature.
For setting the time and other programming options refer to your Honeywell Deluxe Programmable Thermostat instruction booklet provided.